1.) Chamber:
The milling machine used to machine Ertalyte for the ionization
chambers was broken just before August.
I have been promised that I will be able to use it by October 1.
The Tech-Etch foils have arrived and need to be HV tested.
The readout board design was sent to CERN. There is a
software
problem in reading of Gerber Files which needs to be solved.
The connector from the readout board to the VFAT card have been
order by CERN. CERN will also send me several spare connectors
which I intend to use with a pitch adapter to readout out the old
prototypes.
Parts which remaing to be acquired: Charge collector, Output
connectors, G10 nuts & bolts.
2.)Readout electronics
Progress continues on the VFAT card readout. Development of a
Web interface to monitor and control VFAT settings has begun.
Specifications for a
3.) rotator
Tony Forest
Last modified: Thu Nov 29 11:54:55 EST 2007