ULTRA and ULTRA-AS
Ion-Implanted-Silicon Charged-Particle Detectors |
||
|
ULTRA | |
• The new standard for charged-particle detector spectroscopy
• Ultra-thin entrance contact for optimum energy resolution • High geometric efficiency due to close detector-to-can spacing • Rugged and reliable • Gold-plated cans for contacts that last a lifetime • Advanced surface passivation for total device stability • ORTEC quality and reliability • Bakeable at 200°C (require special order) |
|
ULTRA-AS | |
• Low-background version for alpha spectroscopy | |
ULTRA ion-implanted-silicon detectors for alpha and beta spectroscopy are the most advanced charged-particle detectors ever produced. They possess the reliability that has ade ORTEC the sole supplier to NASA of silicon detectors for space applications. | |
Both the entrance and the back contact are ion implanted. The entrance contact is an extremely thin (~500 Å) boron implantation. Since no epoxies are used to mount the ULTRAs, the distance between the silicon surface and the top of the mounting can is <1 mm; this provides maximum geometric efficiency. The rugged front contact, easily cleaned with a solvent-moistened cotton swab, is impervious to finger contact. | |
ULTRA detectors have gold-plated mounting cans. The superior electrical conductivity of gold, which can never oxidize, makes it the choice vs. stainless steel or aluminum. Gold contacts last a lifetime. An advanced surface passivation that covers the critical silicon dioxide layer guarantees absolute device stability. | |
The extremely low leakage current permits specifying the energy resolution at a 1-µs amplifier time constant. | |
Low-background ULTRA-AS detectors are made with special low-background materials and have an optimized depletion thickness to minimize background counts from cosmic rays. All ORTEC Alpha Spectrometers (OCTÊTE Plus, 576A, and SOLOIST) are equipped with either ULTRA-AS detectors or R-Series, Ruggedized Surface Barrier Detectors. All these spectrometers, when equipped with a 450 mm2 detector, have a warranted background performance of £24 counts per day, over the 3- to 8-MeV energy range. | |
The dimensions of the ULTRA and ULTRA-AS detector mounting cans, identical to those of the corresponding size A or R Series detectors, ensure that ULTRA detectors will fit perfectly in any application where A or R Series detectors are being used now. | |
NOTE: Extensive care regarding detector and chamber cleanliness can result in background count levels as low as 0.05 counts/hr/cm2 of active area, corresponding to 6 counts/24 hours, for a 450 mm2 active area. | |
ULTRA and ULTRA-AS detectors are normally supplied in "B" mount, with a rear Microdot connector. Other mounting arrangements are available on request. (Example: For horizontal samples in Model 576A NIM Spectrometers, a closed-back "T" mount with side-mounted Microdot connector is needed. See note below ULTRA and ULTRA-AS tables.) | |
Dimensions and Mounting Arrangement |
|
|
Ordering Information
ULTRA Specify B or "Blind" T** Mount | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
ULTRA-AS Specify B or "Blind" T** Mount | ||||||||||||||||||
~100 µm active depth to minimize cosmic background | ||||||||||||||||||
|
*First three digits of Model No. indicate total system resolution FWHM for 241Am, 5.486-MeV alphas, using standard ORTEC electronics and 1-µs shaping time constants. |
**"Blind" T Mount available only for 300-, 450-, and 600-mm2, except by special order. |
To Order: |
Add the appropriate letter prefix for the mounting desired. |
Example: BU-016-300-100 or TU-016-300-100** |