Attendees: Ashot, Chao G., Chao P., Maxime, Mahbub, Weizhi, Xuefei, Xinzhan, Eugene Weizhi: 1) Comparison between Bosted and MAID (g2p) inelastic algorithm - some electrons below pion production for MAID algorithm (need to be removed) - larger peak for MAID, second resonance larger for Bosted (as in Nick's code), small shift of the peak also - comparison with data: - large PWO angle: data larger than both simulation at first peak - LG angle range: simulation larger at first peak, between simulations at second peak - separating PWO and LG: second peak badly matching for PWO - 1GeV data: width of peak not matching at larger angle - LG region more sensitive to energy cut - shifting second peak in simulation for better match raises super ration of 1% 2) Non linearity correction - <1% shift for lower angle (for Moller energy) - becomes larger when going to larger angle (smaller energy) - normally no effects on inelastic peak 3) Comparison of reconstruction algorithm (5x5, primex island, new island) - very close in position reconstruction - yield change <1% ( a bit more for 5x5 probably due to calibration) - largest difference in energy spectrum in transition region