Proposal #: PR 04-002 Hall
A
Title: Hadronization in Nuclei by Deep Inelastic Electron Scattering
Contact Person: Kebin
Wang (UVa)
Beam Time:
Beam days requested: 15
Tune-up (incl. calibrations) time included in request: 1.5
Basic Equipment
Beam parameters:
Energy: 6 GeV yes
Current: 100 µA yes
Polarization: 0 % yes
Targets:
Nuclei: C, Cu, W, 15 cm LH2 and LD2 yes
Rastering: yes yes
Spectrometers:
both HRS standard setup yes
Special Requirements: none
Cooling may be required for the solid targets to be able to handle beam currents of 100 mA. Because tungsten generally comes in a sintered form, in which it can not stand a high current, it might be advisable to use platinum instead.
Proposal # PR-04-007 Hall: A
Title: Precision Measurement of the πo near Threshold: A Test of Chiral QCD Dynamics
Contact person: Richard Lindgren (UVa)
Beam time:
Beam days requested: 16
Tune-up (incl. calibrations) time included in request: 5
Basic Equipment
Beam parameters:
Energy: 0.8 - 4.0 GeV yes
Current: 5 µA yes
Polarization: 0 % yes
Targets:
Nuclei: 10 cm LH2 no
Rastering: yes yes
Spectrometers:
septum magnets no
both HRS standard setup yes
Big Bite dedicated detector no
RCS lead-glass calorimeter Big Bite calibration no
Special requirements:
1. The proposed 10 cm long target cell with 10 µm walls will represent a serious R&D project.
2. Assumes helium bag inside Big Bite and MWDCs as detectors
3. Requests RCS calorimeter, but this is now part of the BigCal calorimeter
Comments:
None
Proposal # PR-04-011 Hall: A
Title: Photoproduction of Q+ via the g + d -> Q+ + L Reaction
Contact person: Stephen Wood (JLab)
Beam time:
Beam days requested: 7
Tune-up (inc. calibrations) time included in request: 2
Basic Equipment
Beam parameters:
Energy: 1.2 GeV yes
Current: 50 µA yes
Polarization: 0 % yes
Targets:
Radiator Cu 6 % X0 yes
Nuclei: 15 cm LD2 yes
Rastering: yes yes
Spectrometers:
HRSL standard setup yes
plastic scintillator array no
Big Bite with aerogel no
Special requirements:
1. Requires aerogel detector in Big Bite.
2. Requires (undefined) array of plastic scintillators from GEn or SRC experiments
Comments:
Proposal # PR-04-012 Hall: A
Title: High Resolution Study of the 1540 Exotic Sate
Contact person: Bogdan Wojtsekhowski (JLab)
Beam time:
Beam days requested: 47
Tune-up (inc. calibrations) time included in request: 0
Basic Equipment
Beam parameters:
Energy: 2.0, 4.5, 6.0 GeV yes
Current: 100 µA yes
Polarization: 0 % yes
Targets:
Nuclei: Be, C, 50 cm gaseous deuterium no
Rastering: yes yes
Spectrometers:
septum magnets no
HRSL standard setup yes
HRSR standard setup yes
Big Bite spectrometer no
plastic scintillator array no
Comments:
1. Requires development of
a 50 cm long gaseous deuterium target (of which the proposed design with 25 µm thick Al windows will not work and the alternative of 100 µm thick Be windows constitutes a major R&D project)
a new scattering chamber for out-of-plane BigBite positioning
installation of neutron detector (of which the origin is not clear)
2. Provide an estimate of the accidental coincidence rate in BigBite
Proposal # PR-04-015 Hall: A
Title: Precision Measurement
of Longitudinal and Transverse Response Functions of Quasi-Elastic Electron
Scattering in the
Contact person: Seonho Choi (
Beam time:
Beam days requested: 29
Tune-up (inc. calibrations) time included in request: 3
Basic Equipment
Beam parameters:
Energy: 0.4 - 3.6 GeV yes
Current: 50 µA yes
Polarization: 0 % yes
Targets:
Nuclei: 4He, 12C, 56Fe, 208Pb yes
Rastering: yes yes
Spectrometers:
HRSL standard setup yes
HRSR standard setup yes
Special requirements:
None
Comments:
1. Requires so many frequent energy changes which will impact operations in the other Halls to such a degree that it will have to be scheduled for single-hall running.
Proposal # PR-04-018 Hall: A
Title: Elastic Electron Scattering off 3He and 4He
at Large Momentum Transfers
Contact person: Makis Petratos (
Beam time:
Beam days requested: 36
Tune-up time included in request: 0
Basic Equipment
Beam parameters:
Energy: 0.8 - 4.4 GeV yes
Current: 100 µA yes
Polarization: 0 % yes
Targets:
Nuclei: 20 cm 3He, 4He no
Rastering: yes yes
Spectrometers:
HRSE standard setup yes
HRSH standard setup yes
Special requirements:
none
Comments: