    November 30, 2011

    Physics

    Hall A is preparing for a possible beam commissioning run to start on Dec. 12, pending the successful completion of the installation in Hall A. This will be minus the polarized proton target, but will allow commissioning and debugging of several new systems on the beamline, as well as the detector systems. Hall A is also finalizing a project management plan for the Super BigBite projects.

  • Jefferson Lab Weekly Briefs
    January 4, 2012

  • Jefferson Lab Weekly Briefs
    February 8, 2012

    12 GeV Upgrade

    The 12 GeV installation activities for the long shutdown scheduled to begin in May are under development. A weekly Long-Shutdown Planning meeting is being held to integrate the lab-wide installation schedule. With Beneficial Occupancy awarded for the Hall D Complex, ongoing installation work is being coordinated through the Hall D work coordinator.

  • Jefferson Lab Weekly Briefs
    February 15, 2012

  • Jefferson Lab Weekly Briefs
    February 22, 2012

  • Jefferson Lab Weekly Briefs
    February 29, 2012

    12 GeV Upgrade
    The first of two new coldboxes for the new Central Helium Liquefier, CHL2, has been shipped. The C100-1 and C100-2 cryomodules continue to be used for beam operations; as of Feb. 27, they were operating at 85 Megavolts and 80 MV. All 10 cavity strings for the new cryomodules have been completed. Adjustments to the FY12 work plan continue in response to the reduction in FY12 funding relative to the baseline funding profile.

  • Jefferson Lab Weekly Briefs
    April 4, 2012

  • Jefferson Lab Weekly Briefs
    April 25, 2012

  • Jefferson Lab Weekly Briefs
    May 9, 2012

    All-JLab Memo
    The latest "Montage" by Lab Director Hugh Montgomery has been posted to the website. In this newest article, titled "End of an Era," Mont reflects on the accomplishments of the lab during the 6 GeV era.

  • Jefferson Lab Weekly Briefs
    May 16, 2012

    12 GeV Upgrade
    The performance of the C100 cryomodule has now been successfully demonstrated at 104 Megavolts for more than one hour. Preparations are complete for a test at 108 MV with full beam loading this week. Assembly of the sixth C100 has been completed. Installation of the compressors and 4.5 Kelvin coldbox for the Central Helium Liquefier-2 continues. The beam position monitors for arc 10 are ready for installation. The first-article electronics for the stripline beam position monitors passed acceptance testing.