Hall C maintains two general interest mailing lists. To subscribe to these lists, go to the link below and follow the "Subscribing to" instructions. A list of other public Jefferson Lab mailing lists is available.
JEFFERSON LAB SEARCH
-
NEWS ABOUT SHMS DESIGN
Single arm SHMS Monte Carlo has be updated
Note that for simulations for upcoming 12 GeV PACs, one should assume the "standard" 10 cm, 20 cm, and 30 cm cryotargets will be available. Please note that the total beam current available for Hall C and Hall A together will be 85 micro-amps (11 GeV equivalent).
CURRENT SHMS STUDIES AND R&D
-
Project Progress Summary
5 September 1990
Injector and Front-End Test
-Waveguide connections to the first HPA have been done and klystrons are being installed.
-Plumbing for injector service building has been installed. LCW system operational.
-The approach has been defined for cryomodule installation sequence. First cryomodule slated to be installed by 7 September.
-
Project Progress Summary
11 September 1990
Injector and Front-End Test
-First cryomodule is in the tunnel.
-Four klystrons have been installed in the first HPA.
-Copper cavities (chopper 1 & 2, capture section) have been installed on the injector girder as injector reassembly continues.
-Electronics have been reinstalled in high-voltage cage for the gun. First try to run gun from control room this week.
-
Project Progress Summary
18 September 1990
Injector and Front-End Test
-Injector main pump and vacuum manifold installed.
-Fabrication of 5-MeV chicane vacuum chambers started on schedule at University of Illinois.
-Cables for injector magnets and controls pulled.
-First cryomodule has been mounted on its stands and cabling is proceeding.
-
-
Project Progress Summary
23 October 1990
Semi-Annual Review
Project preparations for a November review are continuing, although the date has not been set yet.
Injector and Front-End Test
-Beam viewers in the injector became operational in preparation for a 100-kV beamline test planned for this week.
-